The Fluke Networks DTX-1800 120 cable analyzer performs Level IV accuracy tests of copper and fiber optic networks at speeds up to 10 gigabits and bandwidths up to 900MHz that comply with industry standards including TIA, ISO/IEC, EN, ANSI, and IEEE. The meter performs a Class F autotest in less than 25 seconds and a Category 6 autotest in less than 10 seconds. Testing includes shielded and unshielded twisted pair LAN cabling (STP, FTP, SSTP, and UTP), Category 6A/Class EA permanent link adapters, and Category 6/Class E channel adapters. The DTX module cavity accepts additional test modules as network testing needs and requirements change, including fiber, OTDR (optical time-domain reflectometer), network service, and alien crosstalk modules. The units support coaxial adapters, custom limits, and talk between operators at the main and remote units (headphones included). A wiremap test can be performed to verify that cables are installed correctly. The permanent link adapter provides repeatable accuracy and Category 5e, Category 6, and Category 6A interoperability. Certification tests are performed to TIA, ISO/IEC, EN, ANSI, and IEEE standards. The user-selected test standard automatically determines the test parameters and frequency range for the performed tests. Autotests can be started from the main or remote unit. The fiber autotest performs a dual-fiber, dual-wavelength certification test. The backlit, passive color, LCD display has a diagonal measurement of 3.7"/9.4cm and a resolution of 240 x 320 pixels (W x H). Copper and fiber testers are used by network technicians to troubleshoot, maintain, and optimize performance of copper and fiber optic cabling, hardware connections, and network settings in enterprise networks.
The meter stores up to 250 sets of test results (graphical Category 6), and can store up to 2,000 Category 6 graphical link test results on a separately purchased 128MB multimedia card (MMC). An autosave function ensures that test results are captured and saved. Results can be downloaded to a computer for long-term records retention, or imported to the LinkWare software for analysis and generation of certification reports to provide evidence that the installation has been completed according to standards and best practices (software and USB cable included).
Specifications
Standard link interface adapters (shielded and unshielded twisted-pair LAN cabling) TIA Category 4, 5, 5E, 6 and 6A: 100Ω
ISO/IEC Class C and D: 100Ω and 120Ω
ISO/ IEC Class E, F and FA: 100Ω Category 6A/Class EA permanent link adapters
TIA Category 3, 4, 5, 5e, 6, 6A and ISO/IEC Class C, D, E and EA permanent link
Category 6A/Class EA channel adapters TIA Category 3, 4, 5, 5e, 6, 6A and ISO/IEC Class C, D, E and EA channels
Supported test parameters (selected standard automatically determines the test parameters and frequency range) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (attenuation), Return Loss (RL), RL @ Remote, NEXT, NEXT @ Remote, Attenuation-to-crosstalk Ratio (ACR-N), ACR-N @ Remote, ACR-F (ELFEXT), ACR-F @ Remote, Power Sum ACR-F (ELFEXT), PS ACR-F @ Remote, Power Sum NEXT, PS NEXT @ Remote, Power Sum ACR-N, PS ACR-N @ Remote, Power Sum Alien Near End Xtalk (PS ANEXT), and Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Autotest speed Full two-way autotest of Category 6 Twisted-Pair links in 9 seconds, full two-way autotest of Category 6A and ISO/IEC Class F links in 22 seconds
TIA test standards TIA Category 3, 5e, 6 & 6A per ANSI/TIA-568-C.2
TIA Category 5 (1000BASE-T) per TIA TSB-95
TIA Category 6 per TIA/EIA-568B.2-1
TIA TSB-155 (DTX-1800 only)
ISO/IEC test standards ISO TR 24750
ISO/IEC 11801 Class C, D, and E, Ea & F
EN, ANSI, and IEEE standards EN 50173 Class C, D, E, EA & F
ANSI TP-PMD
IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
IEEE 802.3an 10GBASE-T
Results storage 250 qualification test results (graphical Category 6)
Data output Removable memory card and serial and USB interface
Agency safety certifications and approvals CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2; EN 61326-1; Pollution Degree 2
Power source (main and remote units) 7.4V lithium-ion battery pack with 108VAC to 132VAC adapter/charger
Weight 2.4lb./1.1kg, nominal (without adapter or module)
Dimensions (main unit and remote) 8.5 x 4.4 x 2.4 inches/21.6 x 11.2 x 6 cm (H x W x D)
H is height, the vertical distance from lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.
A copper cable tester is a device for troubleshooting, inspecting, and certifying copper network cabling. Devices range from one-button tools for checking connectivity to complex tools for certifying network installations. Three types of testing include verification, to test whether a connection or cable is functioning correctly; qualification, to test a network's ability to support specific speeds and functionality; and certification, to verify whether a network installation meets industry standards. Cabling contractors, installers, and network technicians use copper cable testers to set up and maintain networks within a building or on a campus in corporate, academic, manufacturing, and other enterprise network environments.